X
Lister Petter, logo

Lister Petter Industrial Generator Sets LAT Saver

Code:

Product Overview

The Lister Petter LAT SAVER Air Cooled Generator Sets—models LAT 8, LAT 15, and LAT 24—offer dependable and fuel-efficient power solutions for industrial and commercial applications. Powered by robust Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel engines, these gensets combine durability with enhanced fuel savings, making them ideal for both continuous and standby power requirements.

Key Features

  • Model Range: LAT 8, LAT 15, LAT 24, with power outputs ranging from 4.4 to 20.2 kVA at 50 Hz and 5.4 to 24.9 kVA at 60 Hz.
  • Fuel Efficiency: Engineered for reduced fuel consumption without compromising performance.
  • Flexible Operation: Options for manual start/stop or remote automatic operation via control module.
  • Reliable Engine: Lister Petter T Series air-cooled diesel engines with direct injection for robust and simple operation.
  • Durable Build: Powder-coated baseplate with forklift pockets and bunded base for secure and clean installation.
  • Comprehensive Controls: Electronic digital control module for precise management and safety.

Technical Specifications

Model LAT 8 | LAT 15 | LAT 24
Engine Type Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel
Power Output 4.4 – 20.2 kVA @ 50 Hz (1500 RPM) | 5.4 – 24.9 kVA @ 60 Hz (1800 RPM)
Alternator Single bearing, 4-pole brushless alternator
Fuel Tank Capacity 66-litre polypropylene tank with fuel gauge
Control System Electronic digital control module with manual and automatic operation options
Base Zirconium phosphated powder-coated with forklift pockets and bund retaining 110% of fluids
Starting System 12V starter battery and leads
Governing Mechanical governing system
Safety Emergency stop button (lock-down type)

Options and Configurations

Open Sets (LAT SAVER)

  • Engine-mounted exhaust silencer
  • Optional features to tailor genset to specific operational needs

Acoustic Sets (LATA SAVER)

  • Soundproof acoustic canopy for noise reduction
  • Residential exhaust silencer for quieter operation
  • Roof-mounted lifting eye bolts for ease of transport
  • External emergency stop button
  • Durable ripple-effect paint finish
  • Earth straps on service doors for grounding safety
  • Large access doors for simplified maintenance
  • Document pocket for manuals and wiring diagrams

Applications

  • Industrial facilities requiring reliable power
  • Construction and site power supply
  • Remote and off-grid power needs
  • Agricultural machinery and irrigation systems
  • Backup and emergency power

Certifications & Standards

  • Manufactured to meet stringent industrial power generation standards
  • Designed for robust performance in demanding environments

50 Hz, 1500 r/min
60 Hz, 1800 r/min
4.4 – 20.2 kVA
5.4 – 24.9 kVA

Back to list

Description

Product Overview

The Lister Petter LAT SAVER Air Cooled Generator Sets—models LAT 8, LAT 15, and LAT 24—offer dependable and fuel-efficient power solutions for industrial and commercial applications. Powered by robust Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel engines, these gensets combine durability with enhanced fuel savings, making them ideal for both continuous and standby power requirements.

Key Features

  • Model Range: LAT 8, LAT 15, LAT 24, with power outputs ranging from 4.4 to 20.2 kVA at 50 Hz and 5.4 to 24.9 kVA at 60 Hz.
  • Fuel Efficiency: Engineered for reduced fuel consumption without compromising performance.
  • Flexible Operation: Options for manual start/stop or remote automatic operation via control module.
  • Reliable Engine: Lister Petter T Series air-cooled diesel engines with direct injection for robust and simple operation.
  • Durable Build: Powder-coated baseplate with forklift pockets and bunded base for secure and clean installation.
  • Comprehensive Controls: Electronic digital control module for precise management and safety.

Technical Specifications

Model LAT 8 | LAT 15 | LAT 24
Engine Type Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel
Power Output 4.4 – 20.2 kVA @ 50 Hz (1500 RPM) | 5.4 – 24.9 kVA @ 60 Hz (1800 RPM)
Alternator Single bearing, 4-pole brushless alternator
Fuel Tank Capacity 66-litre polypropylene tank with fuel gauge
Control System Electronic digital control module with manual and automatic operation options
Base Zirconium phosphated powder-coated with forklift pockets and bund retaining 110% of fluids
Starting System 12V starter battery and leads
Governing Mechanical governing system
Safety Emergency stop button (lock-down type)

Options and Configurations

Open Sets (LAT SAVER)

  • Engine-mounted exhaust silencer
  • Optional features to tailor genset to specific operational needs

Acoustic Sets (LATA SAVER)

  • Soundproof acoustic canopy for noise reduction
  • Residential exhaust silencer for quieter operation
  • Roof-mounted lifting eye bolts for ease of transport
  • External emergency stop button
  • Durable ripple-effect paint finish
  • Earth straps on service doors for grounding safety
  • Large access doors for simplified maintenance
  • Document pocket for manuals and wiring diagrams

Applications

  • Industrial facilities requiring reliable power
  • Construction and site power supply
  • Remote and off-grid power needs
  • Agricultural machinery and irrigation systems
  • Backup and emergency power

Certifications & Standards

  • Manufactured to meet stringent industrial power generation standards
  • Designed for robust performance in demanding environments

Brand

Lister Petter

Lister Petter, logo

Shopping cart

0

No products in the cart.

+30 210 41 10 306
x

    Get in Touch

    If you need to contact us via email please use this form. We will try to get back to you as soon as possible.

    Fields marked with (*) are required