X
Lister Petter, logo

Lister Petter Industrial Generator Sets LAT

Code:

Product Overview

The Lister Petter LAT Air Cooled Generator Sets, including models LAT (8)A, LAT 15(A), and LAT 24(8), are reliable and versatile diesel gensets designed for a variety of industrial and remote power applications. Powered by the Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel engines, these gensets offer robust performance with flexible operation modes—manual start/stop or remote automatic control—making them ideal for demanding environments.

Key Features

  • Model Range: LAT (8)A, LAT 15(A), LAT 24(8) covering power outputs from 4.4 to 20.2 kVA (50 Hz) and 5.4 to 24.9 kVA (60 Hz).
  • Flexible Operation: Manual push-button controls or remote automatic operation with 2-wire circuit activation.
  • Robust Engine: Lister Petter T Series air-cooled diesel engines with direct injection technology ensure durable and efficient performance.
  • Durable Construction: Zirconium phosphated powder-coated baseplates with forklift pockets, bunded base retaining 110% fluids, and anti-vibration mountings for long-lasting operation.
  • Comprehensive Standard Features: Electronic digital control modules, brushless alternators, 66-litre fuel tanks with gauge, 12V starter battery, mechanical governing, and emergency stop.

Technical Specifications

Model LAT (8)A | LAT 15(A) | LAT 24(8)
Engine Type Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel
Power Output 4.4 – 20.2 kVA @ 50 Hz (1500 RPM) | 5.4 – 24.9 kVA @ 60 Hz (1800 RPM)
Alternator Single bearing, 4-pole brushless alternator
Fuel Tank Capacity 66-litre polypropylene tank with contents gauge
Control System Electronic digital control module
Base Zirconium phosphated powder-coated with forklift pockets and bund retaining 110% fluids
Starting System 12V starter battery and leads
Governance Mechanical governing system
Safety Emergency stop button (lock-down type)

Options and Configurations

Open Sets (LAT)

  • Engine-mounted exhaust silencer for noise control
  • Wide range of optional features to customize genset to your needs

Acoustic Sets (LATA)

  • Soundproof acoustic canopy
  • Residential-grade exhaust silencer for reduced noise pollution
  • Roof-mounted lifting eye bolts for safe transportation
  • External emergency stop button
  • Durable ripple-effect paint finish
  • Earth straps on service doors for grounding
  • Large service access doors
  • Document pocket in access door for manuals and wiring diagrams

Applications

  • Industrial manufacturing and processing plants
  • Construction and mining sites
  • Remote locations requiring off-grid power
  • Agricultural and farming operations
  • Emergency standby power supply

Certifications & Standards

  • Engineered and manufactured to meet stringent industrial standards
  • Designed for reliability in tough environmental conditions

50 Hz, 1500 r/min
60 Hz, 1800 r/min
4.4 – 20.2 kVA
5.4 – 24.9 kVA

Back to list

Description

Product Overview

The Lister Petter LAT Air Cooled Generator Sets, including models LAT (8)A, LAT 15(A), and LAT 24(8), are reliable and versatile diesel gensets designed for a variety of industrial and remote power applications. Powered by the Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel engines, these gensets offer robust performance with flexible operation modes—manual start/stop or remote automatic control—making them ideal for demanding environments.

Key Features

  • Model Range: LAT (8)A, LAT 15(A), LAT 24(8) covering power outputs from 4.4 to 20.2 kVA (50 Hz) and 5.4 to 24.9 kVA (60 Hz).
  • Flexible Operation: Manual push-button controls or remote automatic operation with 2-wire circuit activation.
  • Robust Engine: Lister Petter T Series air-cooled diesel engines with direct injection technology ensure durable and efficient performance.
  • Durable Construction: Zirconium phosphated powder-coated baseplates with forklift pockets, bunded base retaining 110% fluids, and anti-vibration mountings for long-lasting operation.
  • Comprehensive Standard Features: Electronic digital control modules, brushless alternators, 66-litre fuel tanks with gauge, 12V starter battery, mechanical governing, and emergency stop.

Technical Specifications

Model LAT (8)A | LAT 15(A) | LAT 24(8)
Engine Type Lister Petter T Series air-cooled, direct injection, naturally aspirated diesel
Power Output 4.4 – 20.2 kVA @ 50 Hz (1500 RPM) | 5.4 – 24.9 kVA @ 60 Hz (1800 RPM)
Alternator Single bearing, 4-pole brushless alternator
Fuel Tank Capacity 66-litre polypropylene tank with contents gauge
Control System Electronic digital control module
Base Zirconium phosphated powder-coated with forklift pockets and bund retaining 110% fluids
Starting System 12V starter battery and leads
Governance Mechanical governing system
Safety Emergency stop button (lock-down type)

Options and Configurations

Open Sets (LAT)

  • Engine-mounted exhaust silencer for noise control
  • Wide range of optional features to customize genset to your needs

Acoustic Sets (LATA)

  • Soundproof acoustic canopy
  • Residential-grade exhaust silencer for reduced noise pollution
  • Roof-mounted lifting eye bolts for safe transportation
  • External emergency stop button
  • Durable ripple-effect paint finish
  • Earth straps on service doors for grounding
  • Large service access doors
  • Document pocket in access door for manuals and wiring diagrams

Applications

  • Industrial manufacturing and processing plants
  • Construction and mining sites
  • Remote locations requiring off-grid power
  • Agricultural and farming operations
  • Emergency standby power supply

Certifications & Standards

  • Engineered and manufactured to meet stringent industrial standards
  • Designed for reliability in tough environmental conditions

Brand

Lister Petter

Lister Petter, logo